Input |
• Rated input voltage |
90÷264Vac |
|
• Line frequency |
50/60Hz |
|
• Input current (max) |
1.2Amax@90Vac |
|
• Leakage current to GND (max) |
1mA max at 50Hz |
|
• Input protection |
• Inrush current limitation • EMI filter • Line fuses |
Output |
• Output voltage |
60W |
|
• Output voltage temp drift |
0.01%/°C typ. |
|
• Output voltage long term stability |
Better than 1% after 24hours typ. |
|
• Adjustable voltage range |
• Vadj. trimmer |
|
• Ripple nois |
See datasheet |
|
• Output power (max) |
60W |
|
• Temp power derating |
2%/°C (50÷60°C see diag.) |
|
• Line regulation |
See datasheet |
|
• Load regulation |
See datasheet |
|
• Hold up time |
20msec |
|
• Test points |
• SF - Fixing bracket |
|
• Output protections |
• Short circuit protection with automatic restart • Overcurrent protection • Overvoltage protection |
General Features |
• DC-DC / AC-DC |
AC-DC |
|
• Efficiency |
87%typ. |
|
• Dieletric withstand voltage |
• Conform to EN 60950 |
|
• Isolation |
• Output - P.E.: 500Vdc |
|
• See table for |
• Output voltage and current • Ripple and noise • Line and load regulation |
|
• Cooling |
Natural convection |
|
• Operating indicator |
• Green led Vout OK |
|
• Other features |
560g |
|
• Operating temperature |
0°C to 60°C |
|
• Storage temperature |
-25°C to 85°C |
|
• Switching frequency |
100KHz typ. |
|
• Weight |
560g |
|
• Comply with |
• EN 50081-1 • EN 61000-6-2 • EN 61000-3-2 cl. A • EN 60950-1 • CE |
|
• Dimensions |
106x140x50 |
|
• Application field |
Din Rail application |